rss
Sex Transm Infect 2008;84:107-110 doi:10.1136/sti.2007.027862
  • Basic science

Chlamydia trachomatis RNA in the environment: is there potential for false-positive nucleic acid amplification test results?

  1. E Meader,
  2. J Waters,
  3. M Sillis
  1. Norfolk and Norwich University Hospital, Norwich, Norfolk, UK
  1. E Meader, Norfolk and Norwich University Hospital, Microbiology Department, Bowthorpe Road, Norwich, Norfolk NR2 3TX, UK; emma.meader{at}nnuh.nhs.uk
  • Accepted 23 October 2007
  • Published Online First 30 October 2007

Abstract

Objectives: The ability of molecular methods to detect low levels of nucleic acid has led to the widespread application of techniques based on nucleic acid amplification tests in microbiological diagnosis. This exquisite sensitivity is recognised in the laboratory to require stringent precautions to avoid contamination, but this is not widely appreciated in clinical settings where samples are initially collected, and may be a particular problem in the non-clinical settings used for sampling as part of the National Chlamydia Screening Programme. There is thus the need to characterise the risk of false-positive results caused by environmental contamination in these areas.

Methods: The extent of environmental contamination of Chlamydia trachomatis (CT) nucleic acid in clinical settings was investigated by swabbing surfaces within the vicinity of specimen collection. Laboratory experiments were designed to monitor the persistence of ribosomal RNA under simulated conditions and to investigate whether contamination of patients’ specimens is a risk if environmental surfaces are contaminated. The Gen-Probe APTIMA Combo 2 system was used for CT rRNA detection.

Results: CT rRNA was detected in swabs taken from examination rooms and toilet areas. Tests showed that this could persist for at least 50 days. The potential for clinical samples to become contaminated as a result of the presence of CT rRNA in the immediate environment was demonstrated in this simulated test.

Conclusion: This study demonstrated that there is a risk of false-positive nucleic acid amplification test results, when samples are taken in an area that is contaminated with target nucleic acid.

Footnotes

  • Competing interests: None declared.

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.