Table 1

Sensitivity and specificity of RPR, NT-MAA, TP-PA and EIA

SpecimensNon-treponemal testsTreponemal tests
NT-MAARPRTP-PAEIA
Sensitivity
n%95% CIn%95% CIn%95% CIn%95% CI
Primary stage
(n=13)
1310077.2 to 1001310077.2 to 1001310077.2 to 1001292.366.7 to 98.6
Secondary stage
(n=43)
4195.384.5 to 98.74195.384.5 to 98.74310091.8 to 1004310091.8 to 100
Early latent stage
(n=28)
2796.482.3 to 99.42810087.9 to 1002810087.9 to 1002810087.9 to 100
Late latent stage
(n=43)
3479.164.8 to 88.63069.854.9 to 0.8144310091.8 to 1004310091.8 to 100
Overall sensitivity
(N=127)
11590.684.2 to 94.511288.281.4 to 92.712710097.1 to 10012699.295.7 to 99.9
Specificity
Non-reactive (n=244)23696.793.7–98.324410098.5–10024410098.5–10024410098.5–100
  • EIA=TrepSure Enzyme Immunoassay.NT-MAA, non-treponemal magnetic particle-based agglutination assay; RPR, rapid plasma reagin; TP-PA, Treponema pallidum particle agglutination assay.